Dig the holes on the ground for the post at every 2m, or 2.5m, or 3m, or 5m , the common hole size is 300mm-500mm . depth is 500mm-1000mm. alignment keep them in the line. Every 5-20m , on the left and right of the post, dig two holes for two braces. the hole size same as the post hole size.
After all the holes finished , Put the posts into the hole. Pay attention to controlling hammer force when the post approaching the depth in construction. Then pouring of concrete like this, the brace install in the same way, and the brace connect with bolts:
A laila pono ʻoe e kali a maloʻo ka lāʻau. A laila hiki iā ʻoe ke hoʻokomo i ka pā pā welded mesh me ka pou. No ka mea, ma ka pou, ua hana mākou i nā makau, i ka wā e hoʻokomo ai i ka uea mesh panel, alignment kau i ka uea ma ka makau, i mea e paʻa ai ka uea mesh panel, eia mākou e paʻi i nā lou me ka hāmare.
Firstly, make one end of the tension wire fixed on the first post with the wire tighterner . Secondly, interval of 15meters, the other end of the tension wire fixed on the post , with the wire tighterner, the wire was straightened. and the wire mesh panel was more stable.